Closed suction catheter has several advantages for both the patient and the healthcare provider. In fact, by avoiding disconnecting the patient from mechanical ventilation, it is possible to limit not only the contamination of the surrounding environment but also the risk of infectious agents that, from the outside, can enter the patient's airways.
Manufacturer of over 10 years experience, supply capacity of over 50000pcs/month.
FEATURES AND BENEFITS
● Features safe and simple access for caring for mechanically ventilated patients (either tracheostomy or endotracheal intubation) on continuous suction without breaking the circuit throughout the patient’s time on the ventilator.
● Special stop valve design seals the catheter tip into an isolated chamber, providing a thorough lavage and cleaning to prevent secretions from clogging the vacuum apparatus.
● It is indicated for 72/24hrs continuous use.
● With 360° swivel adapter provides optimal comfort and flexibility for both patient and nursing staff.
● Open Irrigation port/ One-way needleless Irrigation port/Luer lock irrigation port allows lavage and irrigation, preventing infiltration of secretions and ventilation leakage.
● Replacement of the closed suction system can be identified with a color-coded weekday label.
● Bronchial dilator (MDI) port: Needleless one-way valve prevents incidental leakage before bronchial dilator injection.
● Quality sheer PU sleeve can facilitate operation when advancing the catheter, highly compact sleeve to effectively prevent infiltration of blood and sputum.
● The texture of the suction tip is soft, smooth nozzle without causing damage to mucous membranes.
● Color coded Control switch for quick recognition of the catheter diameter.
● Supplied sterile in peel-open packages. Intended for one-time use.
Code |
Size |
Length |
Control Button |
Description |
KD72-SC1-1054 |
10FR/3.3mm |
54CM |
Black |
Adult |
KD72-SC1-1254 |
12FR/4.0mm |
54CM |
White |
|
KD72-SC1-1454 |
14FR/4.6mm |
54CM |
Green |
|
KD72-SC1-1654 |
16FR/5.0mm |
54CM |
Orange |
|
KD-SC1-1054 |
10FR/3.3mm |
54CM |
Black |
Adult |
KD-SC1-1254 |
12FR/4.0mm |
54CM |
White |
|
KD-SC1-1454 |
14FR/4.6mm |
54CM |
Green |
|
KD-SC1-1654 |
16FR/5.0mm |
54CM |
Orange |
● customized length available (for tracheostomy)
There is indeed a risk of infection when using an obstetric balloon, but this risk is usually low and controllable. The main cause of infection is that the obstetric balloon needs to be inserted throu...
View MoreIn order to avoid possible tracheal tube and bleeding during endotracheal intubation, it is important to first pay attention to adequate preparation and accurate operation skills. Before the operation...
View MoreWhether the design of the resuscitator is optimized for harsh environments is the primary factor that determines its performance stability. Under extreme conditions, such as high temperature, low temp...
View MoreWhat are the advantages of closed suction catheter adult's closed design
Closed Suction Catheter Adult is a key device widely used in modern medical practice, especially in intensive care and anesthesia. Its unique closed design provides significant clinical advantages to patients, making it an indispensable tool in healthcare settings. Ningbo Yuxin Medical Instruments Co., Ltd., as a high-tech enterprise dedicated to the research, development and production of anesthesia respiratory consumables, has accumulated rich experience in the design and manufacturing of closed suction tubes, demonstrating its technological innovation and user experience. profound strength.
The design of the closed suction tube significantly reduces the risk of airway damage. By suctioning without removing the endotracheal tube, medical staff can effectively reduce the mechanical damage to the airway during the operation, especially when the patient's respiratory status is unstable. Compared with the traditional open suction method, the closed suction tube maintains the stability of the tracheal intubation, ensures the integrity of the airway, and reduces interference and potential damage to the airway, which is safer for critically ill patients. Crucial.
In the medical environment, cross-infection is a safety hazard that cannot be ignored. The closed structure design of the closed suction tube effectively prevents the intrusion of external pathogens and significantly reduces the risk of cross-infection. When medical staff use a closed sputum suction tube, they only need to use the built-in valve to suction the sputum without directly touching the outside of the endotracheal tube. This design greatly reduces the chance of bacterial transmission and improves the efficiency in high-level applications such as intensive care and anesthesia. Security in risky environments.
Patient comfort is also an important consideration in the design of closed suction tubes. Traditional open suctioning often causes discomfort to patients, especially during frequent removal of endotracheal tubes. The closed structure of the closed suction tube makes the suction process smoother and can be operated without disturbing the patient's normal breathing, thus significantly improving the patient's comfort. Patients experience less anxiety and discomfort related to suctioning during treatment, and their overall treatment experience improves.
The operation process of the closed sputum suction tube is also relatively simple, and medical staff can complete the sputum suction operation without removing the endotracheal intubation. This convenient operation method not only improves medical efficiency, but also effectively reduces the workload of medical staff. In the intensive care unit, time is often a critical factor. The design of the closed suction tube helps medical staff complete the suction operation quickly and efficiently, ensuring that the patient's respiratory tract remains open at all times.
In addition, closed sputum suction tubes have wide adaptability and are suitable for a variety of clinical scenarios. Closed suction tubes provide effective airway management support, whether in the management of mechanically ventilated patients in the intensive care unit or in post-anesthetized surgical patients. Its various specifications and models can meet the needs of patients of different ages and conditions. This adaptability has made closed suction tubes standard equipment in a variety of medical settings, further solidifying their important role in modern medicine.